Diamondnite Operating Instructions

DIAMONDNITE OPERATION INSTRUCTION

1/ TURN UNIT ON WITH ADJUSTMENT KNOB
2/ WAIT UNTIL WAIT LIGHT GOES OFF AND READY LIGHT COMES ON, APPROXIMATELY 10 SECONDS
3/ HOLD TESTER WITH RIGHT HAND SO THAT YOUR FINGERS ARE RESTING ON THE REAR METAL PLATE AND YOUR OTHER HAND MUST HOLD THE METAL HOLDING THE GEM STONE OR THE METAL TEST PLATE.
4/ LIGHTLY TOUCH THE PROBE TIP IN THE CENTER OF THE GEM STONE. HOLD TESTER PERPENDICULAR TO THE TABLE OF THE GEM FOR ONE SECOND
5/ IF IT'S A SIMULANT OR NON-DIAMOND, NOTHING WILL HAPPEN. IF IT'S A DIAMOND THE BUZZER WILL RING AND THE GREEN LIGHT (DIAMOND) WILL COME ON FOR ABOUT 6 SECONDS. IF IT'S A MOISSANITE THE TONE WILL CHANGE AND THE LIGHTS WILL SWITCH FROM GREEN TO RED (MOISSANITE) WITH IN 1/2 SECOND.
6/ AFTER THE BUZZER IS FIRST HEARD YOU MUST CONTINUE TO TEST FOR ONE SECOND BEFORE YOU TAKE THE PROBE OFF THE GEM STONE. THIS IS BECAUSE THE TEST FOR DIAMOND IS DONE FIRST. THE TEST FOR MOISSANITE IS COMPLETED 1/2 SECOND LATER.
7/ IF THE TONE CHANGES WHILE YOU ARE REMOVING THE PROBE, YOU MUST RE-TEST BECAUSE YOU MAY HAVE CONTACTED THE METAL FINDINGS WHILE REMOVING THE PROBE.
8/ TO SAVE THE BATTERY TURN OFF THE UNIT AFTER TESTING. IF YOU FORGET, THE TESTER WILL REMIND TO DO SO IN THREE MINUTES.
9/ IF THE YELLOW READY LIGHT FLASHES OR DOESN'T COME ON, YOU NEED TO REPLACE THE 9V BATTERY. ALKALINE BATTERIES ARE RECOMMENDED.

WARRANTY
Oris Nelson Enterprise, Inc. provides that each DN1 will be free from defects in material and workmanship for a period of Two years from the date of purchase. (Batteries and Probe Tip are not included in Warranty.) This warranty becomes void by:
1. Unauthorized repair, misuse, modification, alteration, tampering or breaking any factory seal.
2. Accidental damage, neglect or improper use.
Oris Nelson Enterprise shall not be held legally liable or responsible for any error in display indication or the interpretation thereof in the identification of any stones, minerals, gems or gemstones by the DN1 Tester.
US Patent 6,439,766,B1

Oris Nelson Enterprise, Inc.

 

Print

 

Enter content here

visa-mc_emblem.jpg

To order using Visa/MC call: 1-800-748-9442
Store hours 7:30am to 8:00pm cst
 
"Getting a busy signal?" Send order by email or fax.  We'll call you for your credit card information.
Email order@renterprises.net.    
Fax 1-800-748-9446

R Enterprises      Tylertown, MS
All materials (C) 2003 - 2008 R Enterprises    (Privacy Policy)